Below are the most recent publications written about "Chromium Alloys" by people in Profiles.
-
Menown IBA, Mamas MA, Cotton JM, Hildick-Smith D, Eberli FR, Leibundgut G, Tresukosol D, Macaya C, Copt S, Slama SS, Oldroyd KG. Thin Strut CoCr Biodegradable Polymer Biolimus A9-Eluting Stents versus Thicker Strut Stainless Steel Biodegradable Polymer Biolimus A9-Eluting Stents: Two-Year Clinical Outcomes. J Interv Cardiol. 2021; 2021:6654515.
-
Heise G, Arnholt C, Sorrels JH, Morrow B, Kurtz SM, Mihalko WM. Comparison of Inflammatory Cell-Induced Corrosion and Electrocautery-Induced Damage of Total Knee Implants. J Long Term Eff Med Implants. 2019; 29(3):231-238.
-
Urish KL, Hamlin BR, Plakseychuk AY, Levison TJ, Kurtz S, DiGioia AM. Letter to the Editor on "Trunnion Failure of the Recalled Low Friction Ion Treatment Cobalt Chromium Alloy Femoral Head". J Arthroplasty. 2019 01; 34(1):190.
-
Arnholt CM, MacDonald DW, Klein GR, Cates HE, Rimnac CM, Kurtz SM, Kocagoz S, Chen AF. What Is the Incidence of Cobalt-Chromium Damage Modes on the Bearing Surface of Contemporary Femoral Component Designs for Total Knee Arthroplasty? J Arthroplasty. 2018 10; 33(10):3313-3319.
-
MacDonald DW, Chen AF, Lee GC, Klein GR, Mont MA, Kurtz SM, Cates HE, Kraay MJ, Rimnac CM. Fretting and Corrosion Damage in Taper Adapter Sleeves for Ceramic Heads: A Retrieval Study. J Arthroplasty. 2017 09; 32(9):2887-2891.
-
Urish KL, Hamlin BR, Plakseychuk AY, Levison TJ, Higgs GB, Kurtz SM, DiGioia AM. Trunnion Failure of the Recalled Low Friction Ion Treatment Cobalt Chromium Alloy Femoral Head. J Arthroplasty. 2017 09; 32(9):2857-2863.
-
Arnholt CM, MacDonald DW, Underwood RJ, Guyer EP, Rimnac CM, Kurtz SM, Mont MA, Klein GR, Lee GC, Chen AF, Hamlin BR, Cates HE, Malkani AL, Kraay MJ. Do Stem Taper Microgrooves Influence Taper Corrosion in Total Hip Arthroplasty? A Matched Cohort Retrieval Study. J Arthroplasty. 2017 04; 32(4):1363-1373.
-
Baykal D, Siskey RS, Underwood RJ, Briscoe A, Kurtz SM. The Biotribology of PEEK-on-HXLPE Bearings Is Comparable to Traditional Bearings on a Multidirectional Pin-on-disk Tester. Clin Orthop Relat Res. 2016 Nov; 474(11):2384-2393.
-
Kocagoz SB, Underwood RJ, MacDonald DW, Gilbert JL, Kurtz SM. Ceramic Heads Decrease Metal Release Caused by Head-taper Fretting and Corrosion. Clin Orthop Relat Res. 2016 Apr; 474(4):985-94.
-
Fredette EK, MacDonald DW, Underwood RJ, Chen AF, Mont MA, Lee GC, Klein GR, Rimnac CM, Kurtz SM. Does Metal Transfer Differ on Retrieved Ceramic and CoCr Femoral Heads? Biomed Res Int. 2015; 2015:283038.